• Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • News
  • Technical articles
  • Contact
  • +34 900 730 124
  • Customer area
  • UE
  • EN ▾
    • EN
    • ES
    • FR
  • GENESAL ENERGY
    • Company
      • Company
      • Why Genesal Energy?
      • Certifications
      • Institutional Support
      • Looking for talent
      • Shareholders
    • R+D+i
      • Engineering & Manufacturing
      • CETED
    • Communication
      • News
      • Technical articles
      • Newsletter Signup
  • INTERNATIONAL
  • GENERATOR SETS
    • Typology
      • → Diesel
      • Insonorización Catalog & Filter
      • → Gas
      • → Hybrid
      • → Stage V
      • → ECOdesign
      • → HVO
      • Request an offer
    • Personalization
      • → Custom Generators
      • Soundproofing
      • Anti-seismic
      • Low temperatures
      • Dual Frequency
      • Medium Voltage
      • Cogeneration
      • Marine Auxiliary Gensets
    • Applications
      • Infrastructure and transport
      • Power plants
      • Data Centre
      • Services
      • Military
      • Industry and construction
      • Hospitals
      • Wind Farms
    • Case Studies
      • Check out some of the latest installations we’ve carried out around the world.
      • Access
  • AFTER SALES
    • After-sales / Clients
    • Technical assistance
  • Projects
  • Greenesal
  • Contact
  • Menu Menu
You are here: Generator sets1 / Applications2 / Data Center3 / “Turnkey” power to reinforce the security of a data center in Tenerife...
Data Center

“Turnkey” power to reinforce the security of a data center in Tenerife

Extremely reliable and with no room for error.

That’s how generators must be in Data Processing Centers (DPC) or Data Centers, facilities dedicated to housing complex, high capacity computer systems, where a power failure or interruption in mains supply can turn into a catastrophe and generate enormous losses.

Emergency generator sets have an essential mission in these facilities: they are the best security guarantee, the necessary prevention system to avoid endangering all the information contained inside the Data Centers. At Genesal Energy we’ve been supplying this kind of generator sets for many years, units which have to be completely special (for example, it’s important to carefully select the engine and alternator to achieve optimal performance without oversizing them excessively). For this reason, because they have very particular characteristics, at Genesal Energy we design them made-to-measure, according to the client’s requirements and always after analyzing the characteristics of the space in which they must operate.

We’re experts in supplying turnkey and bespoke solutions: we take care of the entire process, from start to finish: from the design and manufacture to the transport, installation along with the processing of all necessary permits, setup of auxiliary elements (fuel, chimneys, etc.), commissioning and maintenance. We offer all services in one.

One of our latest projects of this kind has taken us to the Canary Islands, specifically to Tenerife, where we installed two generator sets for a DPC in Majuelos. They are two 500 kVA soundproof generator sets with a redundant parallel synchronization system.

The Data Center needed to grow, and in this expansion stage it incorporated new 5G communication systems into its installations. These systems require a greater consumption, and as such, there was a need to increase emergency power supply so that, if ever a voltage failure were to occur, the center could continue operating as normal. Our engineers’ solution consisted in two 500 kVA generator sets in parallel with a double-walled 2,000 L fuel tank.

Once the manufacturing process had come to a close, at Genesal Energy, as is usual in these cases, we took care of the logistics and, before carrying out the transport, we managed all required arrangements with the administration entities involved. Due to the location of the Data Center and the characteristics and size of the generator sets as well as their location on the roof of the building, it was also necessary to cut off public access, and so we achieved the necessary permits.

Our engineers’ solution

  • Both gensets operate in parallel with eachother through the efficient management of the system and will start up via a free contact provided by the client when a mains failure occurs. Both units will synchronize and take the load.
  • If the total load is under 70% the power rating of one of the gensets, one of them will disconnect so that only one powers the loads.
  • If the total load is above 70%, the disconnected genset will start up, commencing synchronization with the operating genset.

Thus, the startup of both gensets will alternate depending on operating hours according to a configurable parameter in the control panel so that, if there is a difference in operating hours between both gensets, the one with least hours will remain operating in the case that the load doesn’t surpass 70%.

Previous Previous Previous Next Next Next
123

Features

  • Two symmetrical generator sets to visualize the control panel of both at once.
  • A 2,000 L fuel tank which supplies both gensets.
  • Two generator sets with synchronization panel.
  • C5 paint treatment.
Spain
2xGEN500SI
Client's needsCustomized and turnkey solution to provide power to a DPC.
Technical data

Prime power: 2×450 kVA
Standby power: 2×500 kVA
Voltage: 400 / 230 V
Engine: Scania
Alternator: Leroy Somer

Discover more Genesal Energy’s projects

All projects

Contact

Do you need a generator set?

Fill in the form with your information if you want one of our generator sets or if you have any questions. We will prepare a quotation for you based on your requirements.

Logo Corporativo de Genesal Energy

Customer Service Telephone/Fax:

+34 900 730 124

Customer service team Email

consultas@genesal.com

GENESAL ENERGY

  • Company
  • Why Genesal Energy?
  • Greenesal
  • Certifications
  • We’re looking for talent
  • Client Area

INTERNATIONAL

We operate in over 40 countries worldwide.

EUROPE | AFRICA | LATIN AMERICA | MIDDLE EAST

  • Genesal Energy Mexico
  • Genesal Energy Peru

R&D+i

  • Engineering and manufacturing
  • CETED

GENERATOR SETS

  • Diesel Generator Sets
  • Gas Generator Sets
  • Hybrid Generator Sets
  • Stage V Generator Sets
  • REQUEST A QUOTE

CERTIFICATIONS


ISO 9001 Certification ISO 14001 Certification ISO 45001 Certification
UNE 166002 Certification PYME The Global Compact

COMUNICATION

  • News
  • Technical articles
  • Projects

APPLICATION

  • Transport and infrastructure
  • Power plants
  • Data Centres
  • Services
  • Military
  • Industry and construction
  • Hospitals
  • Wind farms

SAT | AFTERSALES

  • Technical Assistance Service (SAT)
  • Multi-brand Maintenance
Genesal

Parroquia de Rois, b28
Polígono Industrial de Bergondo 15165
Bergondo, A Coruña

+34 900 730 124
consultas@genesal.com

Union Europea

Officially registered as Manufacturer with references:
RII_PYA: 7848
RII_ENV: ENV/2023/000004191
RII_AEE: 7087


Members of

EuropGen

  • Twitter
  • Facebook
  • Linkedin
  • Youtube
  • Instagram
© 2025 Genesal Energy
  • Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • Privacy policy
  • Legal note
Link to: Emergency power for Togo’s first thermal power plant Link to: Emergency power for Togo’s first thermal power plant Emergency power for Togo’s first thermal power plant Link to: Vibrations are an issue. How to avoid them? Link to: Vibrations are an issue. How to avoid them? Vibrations are an issue. How to avoid them?
Scroll to top Scroll to top Scroll to top