• Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • News
  • Technical articles
  • Contact
  • +34 900 730 124
  • Customer area
  • UE
  • EN ▾
    • EN
    • ES
    • FR
  • GENESAL ENERGY
    • Company
      • Company
      • Why Genesal Energy?
      • Certifications
      • Institutional Support
      • Looking for talent
      • Shareholders
    • R+D+i
      • Engineering & Manufacturing
      • CETED
    • Communication
      • News
      • Technical articles
      • Newsletter Signup
  • INTERNATIONAL
  • GENERATOR SETS
    • Typology
      • → Diesel
      • Insonorización Catalog & Filter
      • → Gas
      • → Hybrid
      • → Stage V
      • → ECOdesign
      • → HVO
      • Request an offer
    • Personalization
      • → Custom Generators
      • Soundproofing
      • Anti-seismic
      • Low temperatures
      • Dual Frequency
      • Medium Voltage
      • Cogeneration
      • Marine Auxiliary Gensets
    • Applications
      • Infrastructure and transport
      • Power plants
      • Data Centre
      • Services
      • Military
      • Industry and construction
      • Hospitals
      • Wind Farms
    • Case Studies
      • Check out some of the latest installations we’ve carried out around the world.
      • Access
  • AFTER SALES
    • After-sales / Clients
    • Technical assistance
  • Projects
  • Greenesal
  • Contact
  • Menu Menu
You are here: Generator sets1 / Applications2 / Data Center3 / Genesal Energy supplies 6 containerized soundproofed generator sets to...
Data Center

Genesal Energy supplies 6 containerized soundproofed generator sets to a data centre in Norway

The strategic importance of data centers

Data Centres are facilities that allow companies and users to quickly access data and, due to the function they perform, they have become essential in an increasingly digitalised world. Their electricity consumption is considerable and this high demand is not only used to run the IT equipment, but also to cool these rooms that house it.

Maintaining optimal temperatures in data centers

The optimum operation temperature in a data centre to ensure proper performance of the servers is between 18 and 20°C. To keep the temperature within these values, an uninterrupted power supply is vital. Any brief network outage could paralyse all the activities of a company and cause not only economic losses but also reputational damage that is difficult to recover from in most cases.

Generating sets: guarantee of continuity

For this purpose, redundant supply sources are used to ensure operational continuity in the event of any failure in the electricity grid, namely, electrical generators. An efficient and specialised solution to guarantee the constant availability of electrical energy.

Data Centre generator sets require cutting-edge engineering and experienced personnel. Genesal Energy provides both and for this reason the projects we develop are in great demand in this market.

One of our latest projects in this field has taken us to Norway, where we have supplied a total of six generator sets to power the emergency network of a data centre. The cold climate of this Nordic country was not an obstacle to the success of the project, as the six generator sets were designed to withstand the country’s low temperatures.

The engineering solution: 6 soundproofed generator sets in a container

Six 2250-2500 kVA soundproofed generator sets in a 40 feet HC container ready to work in permanent parallel with the grid. Two were designed with the power output on the right-hand side and four sets, symmetrical to the first two, with the power output on the left-hand side, which facilitated the installation of the power cabling.

Characteristics of containerized soundproof generator sets

  • 4.000 L Certified double-walled fuel tank which provides autonomy for more than 9 hours at 100% load.
  • Connections for fuel transfer from an external tank.
  • High-capacity fuel filtration system.
  • Container floor covered with checker plate.
  • Double starter motor.
  • Double set of batteries.
  • Motorised air inlet and outlet louvers.
  • Heat exchanger integrated in the base frame for heat recovery.
  • Customised power output busbars for easy connection.
  • C3 paint surface treatment, according to ISO12944, in RAL7016 colour.
  • Exhaust gas silencer installed on container, heat-insulated, with external aluminium coating.
  • The sound pressure level at a distance of 1 m is 85 dB.
Norway
6xGEN2500HC
Client's needs11 MW of backup power for the data centre, designed according to TIERIII criteria. Heat recovery by means of a heat exchanger system in the engine.
Technical data

Supply: Soundproofed
Prime Power: 2250 kVA
Standby Power: 2500 kVA
Voltage: 400/230 V
Frequency: 50 Hz
Engine: Mitsubishi
Alternator: Leroy Somer

Discover more Genesal Energy’s projects

All projects

Contact

Do you need a generator set?

Fill in the form with your information if you want one of our generator sets or if you have any questions. We will prepare a quotation for you based on your requirements.

Logo Corporativo de Genesal Energy

Customer Service Telephone/Fax:

+34 900 730 124

Customer service team Email

consultas@genesal.com

GENESAL ENERGY

  • Company
  • Why Genesal Energy?
  • Greenesal
  • Certifications
  • We’re looking for talent
  • Client Area

INTERNATIONAL

We operate in over 40 countries worldwide.

EUROPE | AFRICA | LATIN AMERICA | MIDDLE EAST

  • Genesal Energy Mexico
  • Genesal Energy Peru

R&D+i

  • Engineering and manufacturing
  • CETED

GENERATOR SETS

  • Diesel Generator Sets
  • Gas Generator Sets
  • Hybrid Generator Sets
  • Stage V Generator Sets
  • REQUEST A QUOTE

CERTIFICATIONS


ISO 9001 Certification ISO 14001 Certification ISO 45001 Certification
UNE 166002 Certification PYME The Global Compact

COMUNICATION

  • News
  • Technical articles
  • Projects

APPLICATION

  • Transport and infrastructure
  • Power plants
  • Data Centres
  • Services
  • Military
  • Industry and construction
  • Hospitals
  • Wind farms

SAT | AFTERSALES

  • Technical Assistance Service (SAT)
  • Multi-brand Maintenance
Genesal

Parroquia de Rois, b28
Polígono Industrial de Bergondo 15165
Bergondo, A Coruña

+34 900 730 124
consultas@genesal.com

Union Europea

Officially registered as Manufacturer with references:
RII_PYA: 7848
RII_ENV: ENV/2023/000004191
RII_AEE: 7087


Members of

EuropGen

  • Twitter
  • Facebook
  • Linkedin
  • Youtube
  • Instagram
© 2025 Genesal Energy
  • Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • Privacy policy
  • Legal note
Link to: Welcome 2024! We turn 30 full of positive energy Link to: Welcome 2024! We turn 30 full of positive energy Welcome 2024! We turn 30 full of positive energy Link to: We bring our energy to the Montseny Natural Park, World Biosphere Reserve Link to: We bring our energy to the Montseny Natural Park, World Biosphere Reserve Gas generator in natural environmentWe bring our energy to the Montseny Natural Park, World Biosphere Reserve
Scroll to top Scroll to top Scroll to top