• Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • News
  • Technical articles
  • Contact
  • +34 900 730 124
  • Customer area
  • UE
  • EN ▾
    • EN
    • ES
    • FR
  • GENESAL ENERGY
    • Company
      • Company
      • Why Genesal Energy?
      • Certifications
      • Institutional Support
      • Looking for talent
      • Shareholders
    • R+D+i
      • Engineering & Manufacturing
      • CETED
    • Communication
      • News
      • Technical articles
      • Newsletter Signup
  • INTERNATIONAL
  • GENERATOR SETS
    • Typology
      • → Diesel
      • Insonorización Catalog & Filter
      • → Gas
      • → Hybrid
      • → Stage V
      • → ECOdesign
      • → HVO
      • Request an offer
    • Personalization
      • → Custom Generators
      • Soundproofing
      • Anti-seismic
      • Low temperatures
      • Dual Frequency
      • Medium Voltage
      • Cogeneration
      • Marine Auxiliary Gensets
    • Applications
      • Infrastructure and transport
      • Power plants
      • Data Centre
      • Services
      • Military
      • Industry and construction
      • Hospitals
      • Wind Farms
    • Case Studies
      • Check out some of the latest installations we’ve carried out around the world.
      • Access
  • AFTER SALES
    • After-sales / Clients
    • Technical assistance
  • Projects
  • Greenesal
  • Contact
  • Menu Menu
You are here: Generator sets1 / Applications2 / Airports3 / Mobile power for airport environments: reliability and regulatory compliance...
Airports

Mobile power for airport environments: reliability and regulatory compliance at Manchester Airport

Airports require flexible energy solutions capable of meeting operational needs across different areas of the infrastructure, sometimes far from fixed power sources.

Genesal Energy has designed and supplied Manchester Airport with a mobile generator set delivering power wherever it’s needed, quickly and efficiently.

A GEN440VA Open generator set model was designed to operate as a portable solution within the airport environment. Compliant with European Stage V emissions regulations, the unit can be moved and used across different areas without restrictions, facilitating its integration into maintenance and support operations.

Mobility, efficiency and regulatory compliance

Supplying power autonomously across different airport locations, this set reduces the need to move heavy machinery or install complex installations. This design helps optimise response times and improve efficiency in maintenance tasks, while also contributing to reduced operational costs.

Compact design with high performance

Genesal Energy engineering team developed a design with compact dimensions and an optimised configuration to facilitate transport and operation.

This set reduces the need to move heavy machinery or install complex installations.

It includes a 750-litre bunded fuel tank with leak tray, ensuring high autonomy. Also, an additional silencing system enables compliance with the acoustic limits set by the client.

The unit is completed with a Deep Sea DSE8610 control system, an 800A circuit breaker suitable for synchronisation, a heater to improve starting performance, and sockets adapted to the UK standard, among other elements. These features ensure reliable operation and seamless integration into the airport’s operational environment.

Features

  • Open generator set compliant with Stage V regulations.
  • Silencer GT MX175.
  • Deep Sea DSE8610 MkII control panel.
  • Fuel tank with spill containment tray and 750-litre capacity.
  • Hotstart 2000W heater.
  • Eaton 800 A circuit breaker, suitable for synchronisation.
  • UK-standard control panel sockets, type G.
  • Battery set with easily accessible isolator.
United Kingdom
GEN440VA
Client's needsThe client required a mobile, compact and high-performance generator set capable of complying with Stage V emissions regulations, while ensuring sufficient autonomy to operate in a highly demanding airport environment. The solution needed to provide power supply across different airport locations, optimising maintenance operations and reducing the need to move heavier equipment.
Technical data

Prime Power: 400 kVA
Standby Power: 440 kVA
Voltage: 400/230 V
Frequency: 50 Hz
RPM: 1,500 rpm
Engine: Volvo
Alternator: Mecc Alte

Discover more Genesal Energy’s projects

All projects

Contact

Do you need a generator set?

Fill in the form with your information if you want one of our generator sets or if you have any questions. We will prepare a quotation for you based on your requirements.

Logo Corporativo de Genesal Energy

Customer Service Telephone/Fax:

+34 900 730 124

Customer service team Email

consultas@genesal.com

GENESAL ENERGY

  • Company
  • Why Genesal Energy?
  • Greenesal
  • Certifications
  • We’re looking for talent
  • Client Area

INTERNATIONAL

We operate in over 40 countries worldwide.

EUROPE | AFRICA | LATIN AMERICA | MIDDLE EAST

  • Genesal Energy Mexico
  • Genesal Energy Peru

R&D+i

  • Engineering and manufacturing
  • CETED

GENERATOR SETS

  • Diesel Generator Sets
  • Gas Generator Sets
  • Hybrid Generator Sets
  • Stage V Generator Sets
  • REQUEST A QUOTE

CERTIFICATIONS


ISO 9001 Certification ISO 14001 Certification ISO 45001 Certification
UNE 166002 Certification PYME The Global Compact

COMUNICATION

  • News
  • Technical articles
  • Projects

APPLICATION

  • Transport and infrastructure
  • Power plants
  • Data Centres
  • Services
  • Military
  • Industry and construction
  • Hospitals
  • Wind farms

SAT | AFTERSALES

  • Technical Assistance Service (SAT)
  • Multi-brand Maintenance
Genesal

Parroquia de Rois, b28
Polígono Industrial de Bergondo 15165
Bergondo, A Coruña

+34 900 730 124
consultas@genesal.com

Union Europea

Officially registered as Manufacturer with references:
RII_PYA: 7848
RII_ENV: ENV/2023/000004191
RII_AEE: 7087


Members of

EuropGen

  • Twitter
  • Facebook
  • Linkedin
  • Youtube
  • Instagram
© 2026 Genesal Energy
  • Link to X Link to X Link to X
  • Link to Facebook Link to Facebook Link to Facebook
  • Link to Instagram Link to Instagram Link to Instagram
  • Link to Youtube Link to Youtube Link to Youtube
  • Link to Instagram Link to Instagram Link to Instagram
  • Privacy policy
  • Legal note
Link to: Genesal Energy equips a combined-cycle power plant in Brazil with two high-power, high-autonomy generator sets Link to: Genesal Energy equips a combined-cycle power plant in Brazil with two high-power, high-autonomy generator sets Genesal Energy equips a combined-cycle power plant in Brazil with two high-power,...
Scroll to top Scroll to top Scroll to top