Diesel
low noise emitting,
low power consumption
and 100% reliability.
Innovation while developing.
Our focus on innovating while developing, has allowed us to design complete ranges of standard diesel gensets with a wide variety of configurations permitting extensive flexibility when responding to our clients demands.
5-3.900 kVA | 50/60 Hz | 1.500/1.800 rpm
RANGES
Our diesel gensets are grouped
as per the amount of power they supply:
XS POWER RANGE
For 50 Hz: 5-22 kVA
For 60 Hz: 6,6-22 kVA
The XS power range has been designed for applications where low power output is required.
The gensets consist of a mix of high performance with low carbon emissions, easy maintenance. They are also highly autonomous due to their low fuel consumption coupled with a large interior fuel tank. These gensets are compact and light, they are ideal for domestic environments.
S POWER RANGE
For 50 Hz: 23-110 kVA
For 60 Hz: 23-125 kVA
The S power range is our most versatile range of Genesal Energy gensets.
This range is the combination of high reliability and versatility to adapt to a wide range of applications. These gensets are high performance products with a wide range of power options for both domestic and professional use.
M POWER RANGE
For 50 Hz: 111-385 kVA
For 60 Hz: 126-395 kVA
The M power range is the answer to industrial needs.
For a product to deal with médium output requirements. Within this range, we find the ideal option of a high-performance generator with a multitude of options in order to adapt to the clients specifications; this includes specialised developments, generators for emergency situations, even continued power where there is no grid or the mains power is unreliable.
L POWER RANGE
For 50 Hz: 386-825 kVA
For 60 Hz: 396-940 kVA
Designed to meet high energy demands for areas not considered heavy industry.
One of the highlights of this range is the ability of several GENESAL ENERGY gensets to work in parallel with each other, as well as the ratio power/m2 which these compact gensets supply, therefore they are ideal for supplying substantial amounts of power in small spaces.
XL POWER RANGE
For 50 Hz: 826-3900 kVA
For 60 Hz: 941-3900 kVA
The answer to the needs of heavy industry with high output requirements.
This range of gensets is defined by its ease of installation at the end user; a design entirely adapted to the customer specs; transport versatility in the logistics phase.
Check out our diesel
generators catalog
DIESEL GENSETS
Standard Configuration
Engine
- 12/24 V lead-acid battery and electronic battery charger.
- Engine block coolant heater.
- Protection grid for hot and mobile parts.
- Radiator and cooling fan.
Alternator
- Automatic Voltage Regulation (AVR).
- Single-bearing coupling.
- Short-circuiting capacity: 30 % (3 IN) during 10 seconds.
- IP23 protection.
- Class H insulation.
Control panel and functions
- Automatic digital GEINTEL control panel.
- Modes – Automatic / Manual / Testing / Off.
- Periodical automatic start-up test setting available.
- Automatic event registry (100+ events).
- Battery charging in AS Variant (Automatic Start-Up).
- Compatible with EFI engines.
- Three phase network and genset detection using RMS measures.
- Advanced protection systems for mechanical and electrical components (ANSI codes).
- Modbus RTU communication.
Canopy
- Made with galvanized steel.
- Fireproof, soundproof interior insulation boards.
- 2 lugs for lifting up operations.
- Wide inlets for maintenance and service operations.
- Lockable doors with 1 single key.
- Stainless steel hinges.
- Painting and coating as per customer RAL specifications.
20’/40’ and HC container
- Sea-worthy approved container.
- Fire-retardant, soundproof interior insulation boards.
- 4 lifting points.
- Lateral access with panic bar handle / Emergency stop button.
- Painting and coating as per customer RAL specifications.
Others
- Four pole thermal magnetic circuit breaker.
- Fuel tank.
- Low noise emitting flexible exhaust pipe.
DIESEL GENSETS
OPTIONAL EXTRAS
Engine
- Electronic engine control.
- Coolant Level Sensor.
- Fuel pre-filter and water separator.
- Two stage cyclone filters.
- Remote chiller with plate heat exchangers, dry cooler with circulation pump.
- Manual dump pump and oil filler.
- Nickel Cadmium (Ni -CD) Batteries 12V/24V.
- Battery cut off.
- Air start system.
- Automatic oil filler.
- Centrifugal oil filter.
- Double fuel filter with by-pass system.
- Manual / electrical fuel pump.
- Dual frequency (dual 50-60 Hz).
Alternator
- Medium voltage.
- Bare shaft with two roller bearings.
- Permanent magnet generator (PMG).
- De-misting elements.
- Multiple voltage settings.
- PT100 probes in bearings and coilings.
- Close circuit air-air heat exchangers.
- Tropicalisation, marine adaptation and aggressive industrial environments.
Control panel and functions
- Shared loading and synchronization.
- Expansion module for remote signals.
- Controller with communication CANbus, Modbus, Profibus.
- Remote Control Module via Ethernet: RS232-485 ans SNMP.
- Personalised control panel with PLC (Siemens, Rockwell etc), touch screen & protection relay (ANSI norms).
- Fuel level system for automatic diesel filling with solenoid closing valve.
Canopy
- Stainless steel / aluminium canopy.
- Super silent soundproofing and sound deflectors.
- Power sockets.
- Sand filter incorporated in canopy air-intake.
- Particle filters.
- Removable side panels.
- External fuel transfer connection.
- Adapted to Seismic norms.
- Customised design upon request.
10’/20’/30’/40’ Containers
- Ultra-compact soundproof system, up to 2000 kVA in 6 metres longitude and 85dB.
- Automatic and heated blinds.
- Non-slip floor.
- Adapted to extremely low temperatures (-40ºC).
- High solar protection roof panel.
- Snow deflecting roof panel.
- Fire detection and extinguishing system.
- Adapted to Seismic norms.
- Interior compartments are independent (control room, the genset and fuel tank).
- Control room incorporates climate control.
Others
- 4 poles automatic motorized circuit breaker.
- Fuel tank options: different sizes, double walled, dangerous fluids, drip tray, automatic fuel transfer system, leakage detection.
- Silenced air inlets and outlets for interior compartments.
- Low noise emission exhaust pipe.
- Tailormade installations.
- Corrective and preventative maintenance management.