{"id":49279,"date":"2024-10-21T10:31:30","date_gmt":"2024-10-21T10:31:30","guid":{"rendered":"https:\/\/genesalenergy.com\/fr\/?p=49279"},"modified":"2025-10-20T11:34:53","modified_gmt":"2025-10-20T11:34:53","slug":"comment-calculer-le-groupe-electrogene-dont-vous-avez-besoin","status":"publish","type":"post","link":"https:\/\/genesalenergy.com\/fr\/articles-fr\/comment-calculer-le-groupe-electrogene-dont-vous-avez-besoin\/","title":{"rendered":"Comment calculer le groupe \u00e9lectrog\u00e8ne dont vous avez besoin"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-54208 size-full\" src=\"https:\/\/genesalenergy.com\/wp-content\/uploads\/2024\/10\/genesalenergy-articulos-cualnecesitas-7.jpg\" alt=\"T\u00e9cnicos analizando planos y detalles de un proyecto el\u00e9ctrico en un entorno industrial.\" width=\"822\" height=\"488\" \/><\/p>\n<p><span style=\"color: #626262; font-size: 22px; line-height: 144%;\">Dans les environnements industriels, s\u00e9lectionner un groupe \u00e9lectrog\u00e8ne adapt\u00e9 est une t\u00e2che cruciale qui d\u00e9passe la simple estimation de puissance. Un calcul incorrect peut entra\u00eener des \u00e9quipements surdimensionn\u00e9s, impliquant des co\u00fbts inutiles, ou sous-dimensionn\u00e9s, compromettant l\u2019ensemble des op\u00e9rations.<\/span><\/p>\n<p><span style=\"color: #626262; font-size: 22px; line-height: 144%;\">Voici comment calculer correctement le groupe \u00e9lectrog\u00e8ne n\u00e9cessaire, en tenant compte de tous les facteurs techniques impliqu\u00e9s.<\/span><\/p>\n<h2><span lang=\"es-ES\">\u00c9tapes pour calculer la puissance<\/span><\/h2>\n<h3><span lang=\"es-ES\">\u00c9valuation des charges<\/span><span lang=\"es-ES\">\u00a0<\/span><\/h3>\n<p><span lang=\"es-ES\">Identifiez toutes les charges que le groupe \u00e9lectrog\u00e8ne devra alimenter (machines, syst\u00e8mes \u00e9lectriques, \u00e9quipements de s\u00e9curit\u00e9, etc.). Additionnez les puissances constantes et tenez compte des facteurs de simultan\u00e9it\u00e9 pour \u00e9valuer les charges op\u00e9rant en m\u00eame temps.<\/span><\/p>\n<h3><span lang=\"en-US\">Consid\u00e9ration des pics de d\u00e9marrage<\/span><\/h3>\n<p><span lang=\"en-US\">Certaines machines ont un pic de demande au d\u00e9marrage, souvent 2 \u00e0 5 fois sup\u00e9rieur \u00e0 leur consommation normale :<\/span><\/p>\n<ul>\n<li><strong><span lang=\"en-US\">D\u00e9marrage l\u00e9ger<\/span><\/strong><span lang=\"en-US\"><strong>:<\/strong> Turbines, ventilateurs (x2 \u00e0 x3).<\/span><\/li>\n<li><strong><span lang=\"en-US\">D\u00e9marrage moyen<\/span><\/strong><span lang=\"en-US\"><strong>:<\/strong> Convoyeurs, compresseurs (x3 \u00e0 x4).<\/span><\/li>\n<li><strong><span lang=\"en-US\">D\u00e9marrage lourd<\/span><\/strong><span lang=\"en-US\"><strong>:<\/strong> Grues, \u00e9l\u00e9vateurs (x4 \u00e0 x5).<\/span><\/li>\n<\/ul>\n<p><img decoding=\"async\" src=\"https:\/\/genesalenergy.com\/wp-content\/uploads\/2024\/10\/genesalenergy-articulos-cualnecesitas-6.jpg\" alt=\"T\u00e9cnicos trabajando en el mantenimiento y revisi\u00f3n de un grupo electr\u00f3geno en una planta industrial.\" \/><\/p>\n<h3><span lang=\"es-ES\">Calcul de la puissance totale<\/span><\/h3>\n<ul>\n<li><span lang=\"es-ES\">Additionnez les puissances constantes.<\/span><\/li>\n<li><span lang=\"es-ES\">Tenez compte des pics de d\u00e9marrage et ajoutez un facteur de s\u00e9curit\u00e9 (10 % dans cet exemple).<\/span><\/li>\n<li><span lang=\"es-ES\">Appliquez un facteur de puissance (g\u00e9n\u00e9ralement 0,8) pour obtenir la puissance apparente en kVA.<\/span><\/li>\n<\/ul>\n<h3><span lang=\"es-ES\">Exemple avec tableau<\/span><\/h3>\n<table>\n<tbody>\n<tr>\n<td width=\"88\"><strong><span lang=\"es-ES\">\u00c9quipement<\/span><\/strong><\/td>\n<td width=\"107\"><strong><span lang=\"es-ES\">Puissance constante (kW)<\/span><\/strong><\/td>\n<td width=\"112\"><strong><span lang=\"es-ES\">Facteur de simultan\u00e9it\u00e9<\/span><\/strong><\/td>\n<td width=\"102\"><strong><span lang=\"es-ES\">Facteur de d\u00e9marrage<\/span><\/strong><\/td>\n<td width=\"121\"><strong><span lang=\"es-ES\">Puissance de d\u00e9marrage (kW)<\/span><\/strong><\/td>\n<td width=\"104\"><strong><span lang=\"es-ES\">\u00c9chelon de d\u00e9marrage<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td width=\"88\"><span lang=\"es-ES\">Machine A<\/span><\/td>\n<td width=\"107\"><span lang=\"es-ES\">5<\/span><\/td>\n<td width=\"112\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"102\"><span lang=\"es-ES\">3<\/span><\/td>\n<td width=\"121\"><span lang=\"es-ES\">15<\/span><\/td>\n<td width=\"104\"><span lang=\"es-ES\">1<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"88\"><span lang=\"es-ES\">Machine B<\/span><\/td>\n<td width=\"107\"><span lang=\"es-ES\">8<\/span><\/td>\n<td width=\"112\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"102\"><span lang=\"es-ES\">2<\/span><\/td>\n<td width=\"121\"><span lang=\"es-ES\">16<\/span><\/td>\n<td width=\"104\"><span lang=\"es-ES\">1<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"88\"><span lang=\"es-ES\">\u00c9clairage<\/span><\/td>\n<td width=\"107\"><span lang=\"es-ES\">3<\/span><\/td>\n<td width=\"112\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"102\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"121\"><span lang=\"es-ES\">3<\/span><\/td>\n<td width=\"104\"><span lang=\"es-ES\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"88\"><span lang=\"es-ES\">Compresseur<\/span><\/td>\n<td width=\"107\"><span lang=\"es-ES\">10<\/span><\/td>\n<td width=\"112\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"102\"><span lang=\"es-ES\">4<\/span><\/td>\n<td width=\"121\"><span lang=\"es-ES\">40<\/span><\/td>\n<td width=\"104\"><span lang=\"es-ES\">2<\/span><\/td>\n<\/tr>\n<tr>\n<td width=\"88\"><span lang=\"es-ES\">Ventilateurs<\/span><\/td>\n<td width=\"107\"><span lang=\"es-ES\">4<\/span><\/td>\n<td width=\"112\"><span lang=\"es-ES\">1<\/span><\/td>\n<td width=\"102\"><span lang=\"es-ES\">2<\/span><\/td>\n<td width=\"121\"><span lang=\"es-ES\">8<\/span><\/td>\n<td width=\"104\"><span lang=\"es-ES\">1<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h3>R\u00e9sultats<\/h3>\n<ul>\n<li>Puissance totale constante: 30 kW<\/li>\n<li>\u00c9chelon 1 de d\u00e9marrage: 39 kW<\/li>\n<li>\u00c9chelon 2 de d\u00e9marrage: 43 kW<\/li>\n<li>Puissance n\u00e9cessaire: 2 x 43 kW = 86 kW (+ 10 % de marge de s\u00e9curit\u00e9 = 94,6 kW).<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-large wp-image-49291 aligncenter\" src=\"https:\/\/genesalenergy.com\/fr\/wp-content\/uploads\/sites\/4\/2024\/10\/genesalenergy-articulos-cualnecesitas-3.jpg\" alt=\"\" width=\"822\" height=\"488\" srcset=\"https:\/\/genesalenergy.com\/fr\/wp-content\/uploads\/sites\/4\/2024\/10\/genesalenergy-articulos-cualnecesitas-3.jpg 822w, https:\/\/genesalenergy.com\/fr\/wp-content\/uploads\/sites\/4\/2024\/10\/genesalenergy-articulos-cualnecesitas-3-300x178.jpg 300w, https:\/\/genesalenergy.com\/fr\/wp-content\/uploads\/sites\/4\/2024\/10\/genesalenergy-articulos-cualnecesitas-3-768x456.jpg 768w, https:\/\/genesalenergy.com\/fr\/wp-content\/uploads\/sites\/4\/2024\/10\/genesalenergy-articulos-cualnecesitas-3-705x419.jpg 705w\" sizes=\"auto, (max-width: 822px) 100vw, 822px\" \/><\/p>\n<h2>Impact des conditions environnementales<\/h2>\n<h3>Temp\u00e9ratures extr\u00eames<\/h3>\n<ul>\n<li><strong><span lang=\"es-ES\">Froid<\/span><\/strong><span lang=\"es-ES\"><strong>:<\/strong> N\u00e9cessite des syst\u00e8mes de pr\u00e9chauffage moteur et huile adapt\u00e9e.<\/span><\/li>\n<li><strong><span lang=\"es-ES\">Chaleur<\/span><\/strong><span lang=\"es-ES\"><strong>:<\/strong> Requiert des syst\u00e8mes de refroidissement am\u00e9lior\u00e9s pour \u00e9viter la surchauffe.<\/span><\/li>\n<\/ul>\n<h3><span lang=\"es-ES\">Altitude<\/span><\/h3>\n<p><span lang=\"es-ES\">\u00c0 haute altitude, la densit\u00e9 de l\u2019air diminue, r\u00e9duisant la combustion et la puissance moteur. Ajustez la puissance (r\u00e9duction de 3-5 % tous les 300 m au-dessus du niveau de la mer).<\/span><\/p>\n<h3><span lang=\"es-ES\">Conclusion<\/span><\/h3>\n<p><span lang=\"es-ES\">Chez Genesal Energy, nos ing\u00e9nieurs int\u00e8grent tous ces facteurs pour concevoir des groupes \u00e9lectrog\u00e8nes parfaitement adapt\u00e9s aux conditions environnementales et aux besoins \u00e9nerg\u00e9tiques sp\u00e9cifiques, garantissant performance et fiabilit\u00e9 dans tous les environnements.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dans les environnements industriels, s\u00e9lectionner un groupe \u00e9lectrog\u00e8ne adapt\u00e9 est une t\u00e2che cruciale qui d\u00e9passe la simple estimation de puissance. Un calcul incorrect peut entra\u00eener des \u00e9quipements surdimensionn\u00e9s, impliquant des co\u00fbts inutiles, ou sous-dimensionn\u00e9s, compromettant l\u2019ensemble des op\u00e9rations. Voici comment calculer correctement le groupe \u00e9lectrog\u00e8ne n\u00e9cessaire, en tenant compte de tous les facteurs techniques impliqu\u00e9s. [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":49280,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"article-single-post.php","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[305],"tags":[],"pais":[],"class_list":["post-49279","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-fr"],"acf":[],"_links":{"self":[{"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/posts\/49279","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/users\/6"}],"replies":[{"embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/comments?post=49279"}],"version-history":[{"count":1,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/posts\/49279\/revisions"}],"predecessor-version":[{"id":49909,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/posts\/49279\/revisions\/49909"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/media\/49280"}],"wp:attachment":[{"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/media?parent=49279"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/categories?post=49279"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/tags?post=49279"},{"taxonomy":"pais","embeddable":true,"href":"https:\/\/genesalenergy.com\/fr\/wp-json\/wp\/v2\/pais?post=49279"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}